Skip to main content

 Attached disk of Onboarding VM was Missing or removed from Aria Automation deployment topology

https://knowledge.broadcom.com/external/article?articleNumber=386071


Products

VMware Aria Suite

Issue/Introduction

  • Disk detach was failed from Onboarded VM with "Internal server error", Disk went "Missing" status and removed on deployment topology after Data Collection of vSphere cloud account.

Environment

Aria Automation 8.xx

Resolution

  1. Use Day 2 action "unregister" to Unregister the Onboarded VM from Deployment
  2. After couple of Minutes, VM will be shown in Discovered state. 
  3. Onboard the VM again Tutorial: Onboarding and managing vSphere resources in VMware Aria Automation then will add the attached disks to the Deployment topology

Comments

Popular posts from this blog

Step-by-Step Explanation of Ballooning, Compression & Swapping in VMware

 🔹 Step-by-Step Explanation of Ballooning, Compression & Swapping in VMware ⸻ 1️⃣ Memory Ballooning (vmmemctl) Ballooning is the first memory reclamation technique used when ESXi detects memory pressure. ➤ Step-by-Step: How Ballooning Works  1. VMware Tools installs the balloon driver (vmmemctl) inside the guest OS.  2. ESXi detects low free memory on the host.  3. ESXi inflates the balloon in selected VMs.  4. Balloon driver occupies guest memory, making the OS think RAM is full.  5. Guest OS frees idle / unused pages (because it believes memory is needed).  6. ESXi reclaims those freed pages and makes them available to other VMs. Why Ballooning Happens?  • Host free memory is very low.  • ESXi wants the VM to release unused pages before resorting to swapping. Example  • Host memory: 64 GB  • VMs used: 62 GB  • Free: 2 GB → ESXi triggers ballooning  • VM1 (8 GB RAM): Balloon inflates to 2 GB → OS frees 2 GB → ESXi re...

ESXi Host Troubleshooting Checklist

  🛠️ ESXi Host Troubleshooting Checklist (With Complete Log Locations) ✅ 1. Host Status & Connectivity Check host state in vCenter (Connected / Not Responding / Disconnected) Review CPU, RAM, and datastore usage Validate HA/DRS recommendations ✅ 2. Hardware Health Monitor hardware sensors (CPU, DIMMs, fans, PSU, RAID) Check RAID controller logs via vendor tools View hardware status in: vCenter → Monitor → Hardware Health DCUI → Hardware Status ✅ 3. Network Validation Verify vSwitches, Port Groups, NIC teaming, VLAN tagging Check vmkernel ports (mgmt, vMotion, iSCSI, vSAN) Test reachability using: Shell vmkping < IP > Show more lines Validate physical NIC status and link speed ✅ 4. Storage & Datastore Checks Confirm datastore accessibility Rescan storage adapters (iSCSI/FC/NFS) Validate multipathing (Round Robin / Fixed / MRU) Check datastore latency with esxtop ✅ **5. Critical Logs & Their Locations (Full List) Here are key ESXi log files that every VMware adm...
  vCenter Troubleshooting Tips, Common Issues & Log Locations 🚀 1. General Troubleshooting Approach A. Check service health first For vCenter Server Appliance (VCSA): Shell https : / / < vcenter - FQDN > : 5480 Show more lines Go to Services → Health to verify: vCenter Server ESXi hosts vSphere Client DNS, NTP, DB connections vpxd, vpxd-svcs, vsphere-ui B. DNS & NTP checks vCenter is highly dependent on correct DNS & time sync. Check: Shell nslookup < vcenter - fqdn > nslookup < esxi - host - fqdn > Show more lines Time drift > 5 minutes causes: Login failures vpxd crashes PSC authentication issues C. Check storage/database health Slow DB/storage = UI slow, tasks hung. For VCSA: Shell df - h du - sh / storage / log / * / var / log Show more lines Free up space if partitions hit >80%. D. Restart critical services safely On VCSA: Shell service - control - - status service - control - - stop - - all service - control - - start - - all ...