Skip to main content

 Error while collecting data from vCenter cloud account on Aria Automation 8.x

https://knowledge.broadcom.com/external/article?articleNumber=377182


Issue/Introduction

  • Data collection on vCenter cloud account fails with error 

"java.util.concurrent.CompletionException: com.vmware.photon.controller.model.adapters.vsphere.VsphereAdapterException: The connection with vAPI endpoint can not be established. Cause: null" 

  • Cloud account endpoint marked as suspended after the health check failed for a consecutive number of times. After fixing the issues related with the health check and revalidating the cloud account, enumeration continues to be skipped and doesn't run.
  • Some event seen in provisioning logs:

provisioning-service-app.log

2024-08-29T07:55:52.740Z WARN provisioning [host='provisioning-service-app-##########-#####' thread='xn-index-queries-4' user='provisioning-###########' org='#########-####-####-####-############' trace='########-####-####-####-############' parent='########-####-####-####-############' span='#########-####-####-####-############'] c.v.xenon.common.ServiceErrorResponse.create:85 - message: Failed to send enum request. Endpoint [/resources/endpoints/#########-####-####-####-############] is in SUSPENDED state., statusCode: 400, serverErrorId: ########-####-####-####-############: Caused by null
provisioning-service-app.log.#:1781:"message": "Failed to send enum request. Endpoint [/resources/endpoints/###########-####-####-####-############] is in SUSPENDED state.", 



Environment

VMware Aria Automation 8.x

Cause

More than 10 consecutives connection failures to the endpoint due to expired vCenter password, vAPI Service issues or expired certificate.

Resolution

If assistance with this procedure is desired, please open a support request and reference this KB article.

NOTE: Take a non-memory snapshot of all the vRA nodes, also be sure that there are known good backups to restore from.

  • Access the provisioning-db using this command:

vracli dev psql provisioning-db

  • Health check the endpoint resources with below query:

select document_self_link, name, custom_properties->>'consecutiveFailuresCount' as consecutiveFailuresCount, custom_properties->>'endpointHealthCheckState' as endpointHealthCheckState from endpoint_state;

  • Find the endpoint which has reached 10 failures or is in SUSPENDED state, copy their value in the document_self_link column and use the following commands to reset their failures count to 0 and set the endpoint_state to AVAILABLE:

UPDATE endpoint_state SET custom_properties = jsonb_set(custom_properties, ' {consecutiveFailuresCount}
', '0', true) WHERE document_self_link = '<DOCUMENT_SELF_LINK_VALUE>';
UPDATE endpoint_state SET custom_properties = jsonb_set(custom_properties, '
{endpointHealthCheckState}
', '"AVAILABLE"', true) WHERE document_self_link = '<DOCUMENT_SELF_LINK_VALUE>';

     •  Re-validate & save the cloud account and wait for the data collection cycle to start.

Example:

 

Comments

Popular posts from this blog

Quick Guide to VCF Automation for VCD Administrators

  Quick Guide to VCF Automation for VCD Administrators VMware Cloud Foundation 9 (VCF 9) has been  released  and with it comes brand new Cloud Management Platform –  VCF Automation (VCFA)  which supercedes both Aria Automation and VMware Cloud Director (VCD). This blog post is intended for those people that know VCD quite well and want to understand how is VCFA similar or different to help them quickly orient in the new direction. It should be emphasized that VCFA is a new solution and not just rebranding of an old one. However it reuses a lot of components from its predecessors. The provider part of VCFA called Tenenat Manager is based on VCD code and the UI and APIs will be familiar to VCD admins, while the tenant part inherist a lot from Aria Automation and especially for VCD end-users will look brand new. Deployment and Architecture VCFA is generaly deployed from VCF Operations Fleet Management (former Aria Suite LCM embeded in VCF Ops. Fleet Management...
  Issue with Aria Automation Custom form Multi Value Picker and Data Grid https://knowledge.broadcom.com/external/article?articleNumber=345960 Products VMware Aria Suite Issue/Introduction Symptoms: Getting  error " Expected Type String but was Object ", w hen trying to use Complex Types in MultiValue Picker on the Aria for Automation Custom Form. Environment VMware vRealize Automation 8.x Cause This issue has been identified where the problem appears when a single column Multi Value Picker or Data Grid is used. Resolution This is a known issue. There is a workaround.  Workaround: As a workaround, try adding one empty column in the Multivalue picker without filling the options. So we can add one more column without filling the value which will be hidden(there is a button in the designer page that will hide the column). This way the end user will receive the same view.  
  "Cloud zone insights not available yet, please check after some time" message on Aria Automation https://knowledge.broadcom.com/external/article?articleNumber=314894 Products VMware Aria Suite Issue/Introduction Symptoms: The certificate for Aria operations has been replaced since it was initially added to Aria Automation as an integration. When accessing the Insights pane under  Cloud Assembly  ->  Infrastructure  ->  Cloud Zone  ->  Insights  the following message is displayed:   "Cloud zone insights not available yet, please check after some time." The  /var/log/services-logs/prelude/hcmp-service-app/file-logs/hcmp-service-app.log  file contains ssl errors similar to:   2022-08-25T20:06:43.989Z ERROR hcmp-service [host='hcmp-service-app-xxxxxxx-xxxx' thread='Thread-56' user='' org='<org_id>' trace='<trace_id>' parent='<parent_id>' span='<span_id>'] c.v.a.h.a.common.AlertEnu...